Photodiagnosis and Photodynamic Therapy
Volume 5, Issue 2 , Pages 139-147, June 2008

Autofluorescence detection of tumors in the human lung—Spectroscopical measurements in situ, in an in vivo model and in vitro

  • D. Hüttenberger, PhD

      Affiliations

    • TU Kaiserslautern Department of Physics, Universtity of Kaiserslautern, Erwin-Schroedinger-Strasse, 67663 Kaiserslautern, Germany
    • Corresponding Author InformationCorresponding author. Tel.: +49 1753740829; fax: +49 6312054289.
  • ,
  • T. Gabrecht

      Affiliations

    • EPFL Lausanne, Lausanne, Switzerland
  • ,
  • G. Wagnières

      Affiliations

    • EPFL Lausanne, Lausanne, Switzerland
  • ,
  • B. Weber

      Affiliations

    • Richard Wolf GmbH, 75434 Knittlingen, Germany
  • ,
  • A. Linder

      Affiliations

    • Lungenklinik Hemer, 58675 Hemer, Germany
  • ,
  • H.-J. Foth

      Affiliations

    • TU Kaiserslautern Department of Physics, Universtity of Kaiserslautern, Erwin-Schroedinger-Strasse, 67663 Kaiserslautern, Germany
  • ,
  • L. Freitag

      Affiliations

    • Lungenklinik Hemer, 58675 Hemer, Germany

published online 01 July 2008.

Summary 

To detect bronchial carcinoma by autofluorescence, we measured the spectra of tumor and normal tissue in situ, in an in vivo model and in vitro by fiber optic spectrometer and two-dimensional resolved microspectroscopy. The in situ measurements were performed in bronchi of nine patients with squamous cell carcinoma during regular bronchoscopy with autofluorescence assistance. The fluorescence was monitored with a fiber optical spectrometer under blue light excitation (λ=405nm). In an in vivo model, the resected lobe of a lung was perfused under physiological conditions. Tumorous and normal tissues were examined spectroscopically during perfusion and after blood removal and substitution with formol. In another setup the wavelength dependency of autofluorescence was examined on resected parts of physiological bronchi and central bronchial carcinomas. Under the variation of the excitation from 385 to 465nm the autofluorescence response was monitored with a fiber optic spectrometer. For investigation of the origin of autofluorescence, two-dimensional resolved spectroscopy was performed with the SpectraCube system on several sections of tumor and normal tissues All measurements, performed in vivo, in the in vivo model and in vitro agreed, that the main difference of the autofluorescence between tumor and normal bronchus tissue is the intensity of the fluorescences’ main peak at 505nm. The signal on tumor tissue is in all cases significantly lower than that of normal tissue. The shape of the autofluorescence peaks is in healthy and carcinoma tissue approximately the same with two characteristic minima at 540 and 580nm. After the preparation with formaldehyde those minima disappeared from the spectra. A comparison with the absorption spectra of hemoglobin showed, that the variation of the spectra may be due to the blood content in the tissue. Two-dimensional spatially resolved spectroscopy showed, that the lower intensity of fluorescence in tumor tissue is due to the irregular and low-concentrated formation of fluorescent structures, which seen to be the elastic structures of bronchial tissue.

Keywords: Autofluorescence detection, Autofluorescence, Carcinoma, Lung cancer, Spectroscopy, DAFE, Lung perfusion model

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1572-1000(08)00042-2

doi:10.1016/j.pdpdt.2008.05.002

Photodiagnosis and Photodynamic Therapy
Volume 5, Issue 2 , Pages 139-147, June 2008